M880 ZED NJ
Waist belt transmitter
ZED NJ is the synthesis of the best ergonomic and functional features when Joysticks are not required. Despite the extremely compact dimensions, the control panel can fit a large quantity of selectors, switches, buttons and potentiometers that make it suitable for many types of machines.
Adaptive Frequency Agility (AFA)
As it is based on "AFA" technology, (Adaptive Frequency Agility), it avoids manual frequencies changes. The device continuously searches and selects the less impeded channel among the available ones.
Radio calibration
The response behaviour of the single joysticks may be calibrated directly via radio, thus customising the speed of all crane motions (access protected by PIN code).
Event log
The radio remote controls memorise all events that lead to failures or unexpected stops, as well as the operating hours of the device.
PIN CODE
The new range of radio remote controls allows you to set a customisable safety PIN code, so that the device can only be used by authorised personnel.This is yet another proof that the designs and develops for the products are made with extreme attention to details.
STOP button
The new self-locking button with double reset system ensures maximum safety, in accordance with the European and international safety standards, as well as an uncomparable ease of use.
While it is perfectly protected against unintentional collisions, the STOP button is easily accessible and can be quickly operated with priority.
Joysticks, selection, motion controls and control panel
It's available a wide range of selectors, buttons, switches and potentiometers.
On request it's possible to meet every possible demand in terms of customisation. Furthermore, using the advance technology of digital print, is now achievable to customise markings according to needs.
For more complex configurations, multi-colour solutions allow the operator to identify quickly the various control units, thereby preventing errors or inadvertent activations.
the dual-axis joysticks guarantee a long-life and maintenance-free operation providing superb proportional and step control, and will allow smooth and precise control of handling operations throughout the life cycle of your controller.
Status LEDs
All transmitting units are equipped with LED lights that signal operating status, battery level and fault messages.
- Technical Features
- Standards
- Accessories
- Optional items
- Receiver units
- Download
Technical Data
Size (L x D x H) | 214 x 128 x 162 mm |
Weight (battery included) | max 1030 g |
Range | 100 m |
Max. no. of ON/OFF controls | 56 |
Max. no. of analog controls (optional) | 16 (19) |
Joystick controls UMFS = Unintended Movement From Standstill(*) (ISO 13849-1:2006 6.2.6 architecture) | Up to 16 |
Number of service and safety controls | 3 (start, Horn, Stop) |
Case material | Reinforced nylon UL94 HB |
Supply voltage | 3.6 Vdc |
Absorption | 95 mA |
Max. supply power | 0.35 W |
Battery | NiMH 3.6 V - 2.2 A/h |
Battery autonomy at 20°C with charged and continuosly operated battery | Ca. 22 hours |
Low battery level advanced warning time | Ca. 15 min |
Characters display speed on screen | 100 char/s |
1 STOP command | ISO 13849-1:2006 6.2.7 architcture PL e, Category |
Working frequency 1 | I.S.M Band 433.050-434.790 MHz Number of programmable channels: 69 AFA mode (Adaptive Frequency Agility) or on fixed channel Max. power: 1 mW e.r.p. |
Working frequency 2 | I.S.M. Band 434.040-434.790 MHz Number of programmable channels: 30 AFA mode (Adaptive Frequency Agility) or on fixed channel Max. power: 10 mW e.r.p. |
working frequency 3 | 2.4 GHz, 16 ch |
Buzzer | Internal |
Operating temperature | -25°C ÷ +70°C |
Storage temperature | -40°C ÷ +85°C |
Power supply | Single battery |
Radio transmission | Double |
Analog outputs setting | Wireless Real Time Analog Setting (RTAS) |
LEDs | Link TX, Link RX, Error code |
Protection class | IP 65 |
(*) = varies depending on control configuration
EC Regulations
- EN 300-220-2
- EN 301-489-3
- EN 60950-22
- EN 62368-1
- EN 61000-6-3
- EN 61000-6-2
- EN 61326-3-1
- EN 62311
- EN 60204-32
- EN 13849-1
- UNI EN 13557
- EN 62061
- EN 62745
- EN 17067
Directives:
- R&TTE 1999/5/CE
- RED 2014/53/UE
- EMC 2004/108/CE
- LVD 2006/95/CE
CB36NIMH Battery charger + BE3600 Battery
The supply kits of M880 radio remote controls, it's included a new sturdy and compact battery charger.
Its housing can be easily mounted on the wall and is equipped with a 2.1 jack plug for easy connection to an external power supply unit.
The two convenient LED lights provide information concerning the power/supply status of the battery charger, as well as the charge progress status.
The charging process is managed by an electronic system, which ensures optimal and quickest charging cycles.
The supply kit also includes 2 removable and rechargeable NiMH batteries, each of which can ensure up to 22 hours of continuous operation and significant autonomy.
CB36NiMH BATTERY CHARGER
Power supply | 11 ÷ 30 Vdc |
Absorption | max 400 mA |
Battery type | 3,6 V NiMH |
Charging current | 900 mA |
Max. charging time | 2 hours and 20 minutes |
Operating temperature | 0°C ÷ +35°C (+32°F ÷ +95°F) |
Storage temperature | -40°C ÷ +85°C (-40°F ÷ +185°F) |
Size (W x D x H) | 80 x 30 x 120 mm |
Weight | 250 g |
Protection class | IP 20 |
Tilt sensor
This device can recognize unnatural iclination angles of the transmitting unit occuring in typical emergency situations:
- fall and trip over of the radio remote control
- loss of balance by the operator
The Tilt Sensor operating mode can be set according to the customer requirements and to the required of safety: from the simple activation of predefined functions (i.e. horn signal), up to the suspension of all functions of the radio remote control.
Connection configuration via serial cable
The transmitting units of the ZED series ranges may be equipped with a socket for serial connection to the receiving unit.
With direct cable connection, radio transmission is by-passed. This helps avoid potential problems due to signal disturbances, dead battery or situations in which the product is used in areas where radiofrequencies are not permitted.
KAPTA Card
KAPTA option allows to pair a new transmitter to a receiver in few seconds.
For this purpose the transmitting units include a wireless reader and the receiving units come with a smart card.
KAPTA pairing procedure guarantees permanent and exclusive control.
M880 S
RECEIVING UNIT MODEL | M880 S AC | M880 S DC Harting connector (PCB415) | M880 S DC AMP Automotive (PCB410) |
Power supply | 24Vac (50-60HZ) 11÷30 Vdc | 11÷30 Vdc | 11÷30 Vdc |
Safety control | 1 safety-enable relay, 2 STOP relays | 1 safety-enable relay, STOP relays | 1 safety-enable relay, 2 STOP relay |
Max. no. of ON/OFF controls | 14 relays | Up to 14 MOSFET | 8 MOSFET |
2 STOP relays | ISO 13849-1:2006 6.2.7 architecture, (PLe Cat 4) or ISO 13849-1:2006 6.2.6 architecture, (PLc Cat 1) (with ARES2 C) (with WAVE2 C) | ISO 13849-1:2006 6.2.7 architecture, (PLe Cat 4) or ISO 13849-1:2006 6.2.6 architecture, (PLc Cat 1) (with ARES2 C) (with WAVE2 C) | ISO 13849-1:2006 6.2.7 architecture, (PLe Cat 4) or ISO 13849-1:2006 6.2.6 architecture, (PLc Cat 1) (with ARES2 C) (with WAVE2 C) |
Max. no. of analog controls | N.D. | 4 | N.D. |
Service commands | Start, Horn | Start, Horn | Start, Horn |
Serial Ports | N.D. | CAN, RS232, RS485 | CAN, RS232, RS485 |
Analog commands | N.D. | 0÷20mA, 4÷20mA, 0Vdc - (Vdc-3) with Vccmax=28Vdc | N.D. |
Operating temperature | -25°C ÷ +60°C | -25°C ÷ +60°C | -25°C ÷ +60°C |
Storage temperature | -40°C ÷ +85°C | -40°C ÷ +85°C | -40°C ÷ +85°C |
Size (W x D x H) | 127 x 70 x 147 mm | 127 x 70 x 147 mm | 127 x 70 x 1447 mm |
Weight | 630 g | 630 g | 630 g |
| YES (If AMP Automotive no o serial cable) | SI | SI (If AMP Automotive no serial cable) |
Integrated blinklight | YES | NO | NO |
| YES (If Harting or AMP Automotive no external antenna) | YES (If harting or AMP Automotive no external antenna) | NO |
Protection class | IP66 | IP66 | IP66 |
M880 L
RECEIVING UNIT MODEL | M880 S AC | M880 S DC Harting connector (PCB415) | M880 S DC AMP Automotive (PCB410) |
Power supply | 24Vac (50-60HZ) 11÷30 Vdc | 11÷30 Vdc | 11÷30 Vdc |
Safety control | 1 safety-enable relay, 2 STOP relays | 1 safety-enable relay, STOP relays | 1 safety-enable relay, 2 STOP relay |
Max. no. of ON/OFF controls | 14 relays | Up to 14 MOSFET | 8 MOSFET |
2 STOP relays | ISO 13849-1:2006 6.2.7 architecture, (PLe Cat 4) or ISO 13849-1:2006 6.2.6 architecture, (PLc Cat 1) (with ARES2 C) (with WAVE2 C) | ISO 13849-1:2006 6.2.7 architecture, (PLe Cat 4) or ISO 13849-1:2006 6.2.6 architecture, (PLc Cat 1) (with ARES2 C) (with WAVE2 C) | ISO 13849-1:2006 6.2.7 architecture, (PLe Cat 4) or ISO 13849-1:2006 6.2.6 architecture, (PLc Cat 1) (with ARES2 C) (with WAVE2 C) |
Max. no. of analog controls | N.D. | 4 | N.D. |
Service commands | Start, Horn | Start, Horn | Start, Horn |
Serial Ports | N.D. | CAN, RS232, RS485 | CAN, RS232, RS485 |
Analog commands | N.D. | 0÷20mA, 4÷20mA, 0Vdc - (Vdc-3) with Vccmax=28Vdc | N.D. |
Operating temperature | -25°C ÷ +60°C | -25°C ÷ +60°C | -25°C ÷ +60°C |
Storage temperature | -40°C ÷ +85°C | -40°C ÷ +85°C | -40°C ÷ +85°C |
Size (W x D x H) | 127 x 70 x 147 mm | 127 x 70 x 147 mm | 127 x 70 x 1447 mm |
Weight | 630 g | 630 g | 630 g |
| YES (If AMP Automotive no o serial cable) | SI | SI (If AMP Automotive no serial cable) |
Integrated blinklight | YES | NO | NO |
| YES (If Harting or AMP Automotive no external antenna) | YES (If harting or AMP Automotive no external antenna) | NO |
Protection class | IP66 | IP66 | IP66 |
M880 H
RECEIVING UNIT MODEL | M880 H AC | M880 H DC |
| 24 Vac (50-60Hz), 68VA, max 2.8A | 11÷30Vdc, max 4A @11Vdc, 44W |
Safety control | Up to 6 safety-enable relays, 2 STOP relays | Up ot 6 safety-enable relays, 2 STOP relays |
Max. no. of ON/OFF controls | 73 relays or MOSFET | 73 relays or MOSFET |
Max. no. of analog controls | 32 | 32 |
Service commands | Start, Horn, Timed-relay | Start, Horn, Timed-relay |
2 STOP relays | ISO 13849-1:2006 6.2.7 architecture (excluding ARES2 C) (excluding WAVE2 C) | ISO 13849-1:2006 6.2.7 architecture (excluding ARES2 C) (excluding WAVE2 C) |
Input port | CAN, Serial | CAN, Serial |
Proportional commands |
| 0÷20mA, 4÷20mA, 0Vdc - (Vdc-3) with Vccmax=28Vdc, 0 ÷ ±10Vdc PWM 0÷1,4A (F=40÷150Hz; F=200÷600Hz; F=600÷1000Hz), 25%-50%-75% Vcc |
Communication protocols | CAN (ID 11-29 bit) | CAN (ID 11-29 bit) CANOpen (ID 11-29 bit) RS232/RS485 |
Operating temperature | -25°C ÷ +70°C | -25°C ÷ +70°C |
Storage temperature | -40°C ÷ +85°C | -40°C ÷ +85°C |
Size (W x D x H) | 205 x 130 x 280 mm | 205 x 130 x 280 mm |
Protection class | IP66 | IP66 |
M880 M AC
RECEIVING UNIT MODEL | M880 M AC |
Power supply | M AC: 12-30 Vdc / 24 Vac (50-60 Hz) |
Safety controls | 2 STOP, 1 Safety-Enable |
Max. no. of ON/OFF controls | 24 relays (20 NO; and 4 NC/NO) |
Max. no. of analog controls | 4 |
Service commands | Start, Lamp, (Between i 24 relays) |
| ISO 13849-1:2006 6.2.7 architecture (excluding ARES2 C) (excluding WAVE2 C) |
Input port | CAN, Serial 232, 485 |
Proportional commands | 0÷20mA, 4÷20mA, 0Vdc - (Vdc-3) con Vccmax=28Vdc, 0 ÷ ±10Vdc 25%-50%-75% Vcc |
Communication protocols | CAN (ID 11-29 bit) CANOpen (ID 11-29 bit) RS232/RS485 |
Operating temperature | -25°C ÷ +70°C |
Storage temperature | -40°C ÷ +85°C |
Size (W x D x H) | 180 x 73 x 120 m |
Protection class | IP20 |