TWO WAY TRANSMISSION with data DISPLAY
New technological and aesthetic restyling for Wave 2. One of the novelties is the substitution of the NiMH Battery with a Li-ion polymer battery which allows an uninterrupted use of the radio remote control up to 25 hours.
New functions, like the automatic frequency change with “AFA” technology (Adaptive or Automatic Frequency Agility), a continuous monitoring from a PC with a dedicated diagnostic tool, the PIN Code option to restrict the use of the radio remote only to authorized personnel, a LED that allows to have the sight of pushbuttons in dark workplaces, under poor lighting conditions and at night, are nice assets to have.
Unlike the previous model, the new pushbutton Wave 2 S can be equipped with a graphical display.Wave2 is ideal for electric hoists, overhead cranes, conveyors, small tower cranes, etc.
Status LEDs
Colored LEDs report about the status of the radio link, the battery charge level and make the diagnosis of anomalies.
Adaptive Frequency Agility (AFA)
It prevents the risk of interferences. The device continuously searches and selects the less-impeded channel among the available ones.
- Technical Features
- Standards
- Accessories
- Optional Items
- Receiver Unit
- Special Function
- Download
Technical Features
- Dimensions WAVE2S 75x43x180 mm
- Weight WAVE2S 375g
- Power supply 3,7 VDC with Li-ion battery
- Frequency band 433.05 – 434.79 MHz (69 channels) / 2,4 GHz (16 channels)
- Range 100 meters
- Autonomy with fully charged battery about 25 hours with Li-ion battery
- Safety performance STOP function (EN ISO 13489-1) PL
- Protection degree IP65
- Operating temperature -25° +55°
- Storage temperature -40° + 85°
EC Regulations
- EN 300-220-2
- EN 301-489-3
- EN 60950-1
- EN 61000-6-2
- EN 62311
- EN 60204-32
- ISO 13849-1
- UNI EN 13557
- EN 62061
- 2006/42/CE
- R&TTE 1999/5/CE
- RED 2014/53/UE
- EMC (2014/30/CE)
BATTERY CHARGER CB36NIMH
Included in the supply of M880 remote control also a new battery charger with a compact and robust design.
Its case is designed to be fixed to the wall and is equipped with 2.1 jack connection for the connetcion to external power through plug.
Two pratical status LEDs provides information about the activation/supply status of the battery charger and about the progress of the charging.
The electronic managemente of the charging process ensure always optimal charging cycles in the shortest time possible.
Technical Features
- Power supply 11÷30 Vdc
- Max power consumption 400 mA
- Tiype of batteries 3,6 V NiMH
- Charging current 900 mA
- Max charging time 2 hours and 45 minutes
- Operating temperature 0°C ÷ +35°C (+41°F ÷ +113°F)
- Storage temperature -40°C ÷ +85°C (-40°F ÷ +185°F)
- Dimensions (WxDxH) 80 x 30 x 120 mm
- Weight 250 g
- Protection degree IP 20
One Step Push-button
Optional command of selectable choice between rotary switch, potentiometer, 2 or 3 stationary, etc.
Selector Level
Available in 2 or 3 positions with selection with stable or spring return in center position.
Rotary Switch
Switches up to 10 positions can be combined with relay functions or to particular programming software for the selection of receivers in MTRS.
Torch
Keypad illumination for operations in the darkness or torch. Can be combined with a light sensor.
PITOOL
The tool lets you connect the transmitter or receiver to undergo diagnose to a PC. The data may be visualized by means of an easy and intuitive graphical interface and then be saved on your PC in editable format.Two version available: STANDARD – tx can be connected to the tool only via cable; PLUS – besides the cable connection, the device can be connected in wireless mode. This way, the diagnosis and programming tasks can be performed even without having access to the connector on the device. (ex: the RX is positioned at the top of a tall crane).
Enabling Switch
The “enabling switch” is a special component that improves safety of machinery operating in hazardous areas thanks to its design that determines if the user is conscious. This 3 position device activates a machine or a function only when it is a position 2 meaning the operator is present and vigilant. Applicable standard are: EN60947-5-1, EC60947-5-1, UL508, CSA C22.2 No.14
M880 H
M880 H AC Receiver
- Supply voltage 24Vac (50-60Hz), 68VA, max 2,8A
- 45-240Vac (50-60Hz), 45VA, max 1,1A @45Vac
- Security commands Fino a 6 safety-enable relays, 2 Stop relays
- Max number of ON/OFF commands 73 relays o MOSFET
- Max number of analog commands 32
- Service commands Start, Horn, Timed-relay
- 2 STOP relays ISO 13849-1:2006 6.2.7 architecture (escluso ARES2 C)
- Entrance CAN, serial
- Communications protocol CAN (ID 11-29 bit) - CANOpen (ID 11-29 bit) - RS232/RS485
- Operating temperature -25°C +70°C
- Storage temperature -40°C ÷ +85°C
- Dimensions (LxPxA) 205 x 280 x 130 mm
- Degree protection IP66
M880 H DC Receiver
- Supply voltage 11-30Vdc, max 4A @11Vdc, 44W
- Security commands Fino a 6 safety-enable relays, 2 Stop relays
- Max number of ON/OFF commands 73 relays o MOSFET
- Max number of analog commands 32
- Service commands Start, Horn, Timed-relay
- 2 STOP relays ISO 13849-1:2006 6.2.7 architecture (escluso ARES2 C)
- Entrance CAN, serial
- Proportional commands 0÷20mA, 4÷20mA, 0Vdc - (Vdc-3) con Vccmax=28Vdc, 0 ÷ ±10Vdc - PWM 0÷1,4A (F=40÷150Hz; F=200÷600Hz; F=600÷1000Hz), 25%-50%-75% Vcc
- Communications protocol CAN (ID 11-29 bit) - CANOpen (ID 11-29 bit) - RS232/RS485
- Operating temperature -25°C ÷ +70°C
- Storage temperature -40°C ÷ +85°C
- Dimensions (LxPxA) 205 x 280 x 130 mm
- Degree protection IP66
M880 L Receiver
M880 L AC Receiver
- Supply voltage 24-240Vac (50-60Hz), 30VA, max 1,2A @24Vac
- Security commands Safety-enable relay, 2 Stop relays
- Max number of ON/OFF commands 20 relays o MOSFET
- Max number of analog commands 8
- Service commands Start, Horn, Timed-relay
- 2 STOP relays ISO 13849-1:2006 6.2.7 architecture (escluso ARES2 C)
- Entrance CAN, serial
- Communications protocol CAN (ID 11-29 bit) - CANOpen (ID 11-29 bit) - RS232/RS485
- Operating temperature -25°C ÷ +70°C
- Storage temperature -40°C ÷ +85°C
- Dimensions (LxPxA) 145 x 65 x 225 mm
- Degree protection IP66
- Supply voltage 11-30Vdc, max 2A @11Vdc
- Security commands Safety-enable relay, 2 Stop relays
- Max number of ON/OFF commands 20 relays o MOSFET
- Max number of analog commands 8
- Service commands Start, Horn, Timed-relay
- 2 STOP relays ISO 13849-1:2006 6.2.7 architecture (escluso ARES2 C)
- Entrance CAN, serial
- Proportional commands 0÷20mA, 4÷20mA, 0Vdc - (Vdc-3) con Vccmax=28Vdc, 0 ÷ ±10Vdc ,PWM 0÷1,4A (F=40÷150Hz; F=200÷600Hz; F=600÷1000Hz), 25%-50%-75% Vcc
- Communications protocol CAN (ID 11-29 bit) - CANOpen (ID 11-29 bit) - RS232/RS485
- Operating temperature -25°C ÷ +70°C
- Storage temperature -40°C ÷ +85°C
- Dimensions (LxPxA) 145 x 65 x 225 mm
- Degree protection IP66
M880 M Receiver
M880 M AC Receiver
- Supply voltage 12-30 Vdc / 24 Vac (50-60 Hz)
- Security commands STOP, Safety - Enable
- General Commands 24 relè (20 N.O. e 4 N.C./N.O.)
- Service commands Start, Horn (in the 24 relè)
- Entrance CAN, serial
- Communications protocol CAN (ID 11-29 bit) - CANOpen (ID 11-29 bit) - RS232/RS485
- Operating temperature -25°C ÷ +70°C
- Storage temperature -40°C ÷ +85°C
- Dimensions (LxPxA) 180 x 120 x 73 mm
- Degree protection IP20
OPTIONALS
Remote Antenna
The flexibility of its external antenna with extension cable allows you to place it at the point of reception. This option will be of great help in overcoming any obstacles to the radio transmission between transmitter and receiver, so as to ensure maximum range and better communication in all conditions of use. The external antenna is supplied in combination with standard cables of different lengths (2.5 m - 5 m - 10 m).
Flash
Robust and effective blinking can be directly connectedspecially dedicated to the relay inside of all our units receivers.Once connected, the flashing light will turn on with the ignition and radio remain operational throughout the period of use to guarantee the communication between transmitter and receiver.
ATEX Box
Device group II. Device intended to be used in environments where there is a probability that explosive atmospheres; Level of protection: category 2. Intended use in environmentswhere there is a likelihood that explosive atmospheres caused by gases, vapors, mists or mixtures of air and dust; protection system potentially explosive gas and dust. The unit remains powered and operational in zones 1, 2 (G) and 21, 22 (D);Housing explosion-proof, temperature class 85 ° C; Totally protected against dust and powerful water jets (IP66) box set up with a cable gland 1 "IOS7/1RC and ¾" IOS7/1RC barrier for armored cables with specifications: Ex ATEX Exd ll2GD The C IP 66, Range 70 m without obstacles.
Configuring Multi-Receiver and/or Multi-transmitter
The system MTRS allows each receiver to be able to recognize a maximum of 4 transmitters (series of receivers L and M) and 8 transmitters (series of receivers H), with which to operate one at a time, and each transmitter to operate with a up to 16 receivers simultaneously.
It 'also possible, by the function of LOG-LOG-ON and OFF to trade receiver while maintaining control and security. This allows the sharing of equipment by multiple operators.
Start Under Control
With this option, you can activate only if you point the remote control toward the trasmittemte 'additional receiver units called iREADY.The transmission of the start signal takes place by means of an infrared beam in combination with the normal radio signal, in fact the transmitter with option iReady is equipped with two LEDs for infrared transmission.
This obliges the 'operator to perform the start at a certain distance and position relative to the machine, to avoid inadvertent and unwanted goodwill.Once you start, the normal commands work on radio.